Procedure 2 mount fan coil unit can stand or lie on floor or hang from ceiling or wall.
Fan coil unit installation guide.
Remove coil mounting screw securing coil assembly to right side casing flange.
Note to ensure proper drainage for horizontal installations unit must be installed so it is within 1 8 in.
Installation instructions supplied with kit for proper installation.
Drill the hole for the angle nut on the ceiling and fix the hanging rod.
Hl series d horizontal low profile fan coil unit.
N series f series and v series tec3000 color screen product bulletin catalog sales flyer.
The dimensions of the installation template are the same as those of the.
Preface krueger fan coils represent a prudent investment which can with proper installation operation and regular maintenance give trouble free operation and long service.
Fora coils use kit part no.
496 01 5503 02 horizontal right conversion of units with a coils 1.
Unit installation measure and mark the position for the hanging rod.
1 communication to fan coil pcb 2 power supply wire to fan coil unit 3 fuses 5 a 250 v 4 yc y1.
This process accommodates small scuttle holes and limiting entrances to installation sites figure 1.
Connection of first valve.
Fem4x6000b rem4x6000b and fxm4x4800 6000 fan coils are two piece modular units.
Installation instructions fan coils.
Level of the length and width of unit.
N for horizontal installation ceiling mounting it is advisable to use m8 thre aded bars screw anchors suitable for the unit s weight and to arrange for the positioning of the unit using 2 m8 bolts and a washer the diameter of which is suitable for inserting the slot and for then fixing the unit.
This allows for modular unitstobedisassembledandcomponentsmovedseparately to installation area for reassembly.
Install or service any unit without following safe practices regarding mechanical equipment.
The ekrp1c11 can only be used to connect the valves.
Your equipment is initially protected under the.
Installation guide operating manual.
Use fireproof resilient gasket 1 8 to 1 4 in 3 to 6 mm thick between duct unit and floor.
The functions mentioned in the installation manual of the ekrp1c11 can not be used.
Unit installation about fan coil installation please refer to the dimensional drawings and installation diagram.
Figure 2 upflow installation.
Fix the standard unit to the ceiling or wall using at least 4 of the 6 slots.
Check on dimensions in use.
Only use the accessories provided by daikin to install the option.
Do not drill any holes in the casing of the unit to install the option.
Allow space for wiring piping and servicing unit.
Hl series c horizontal low profile fan coil unit.
Remove blower and coil access panel and fitting panel refer to figure 6.
P series t701dfp installation guide operating manual.
The fan coil should be connected with the cooling or heating medium pipe after the duct system is purged in case of the heat exchanger being blocked.
Fem4x fem4p rem4x fxm4x 6 specifications are subject to change without notice.