I ve been wrestling with an electric radiant heat system that i installed roughly 6 years ago in my upstairs bathroom.
Floor heat thermostat with gfi.
Why is my thermostat display sideways.
Option one 1 ac112 01 floor sensor ordered separately.
Is an electric floor heating thermostat the same as regular thermostats.
Required for floor heating applications only guidelines turn off.
The electric cables or mats warm your floor and are controlled by a thermostat that has a gfci installed in it for optimal safety and comfort.
A gfci in floor heating and a smart thermostat.
What can i do if my old thermostat has stopped working.
Paired with a smart thermostat designed to control in floor heating and a working gfci you and your family will stay safe and warm year.
If you have radiant floor heating and an imbalance within the electrical currents occurs the gfci in the radiant heat thermostat will automatically and instantly disconnect the electrical lines from the.
Troubleshooting a gfi issue.
Why does my thermostat say test monthly.
Radiant floor heating is a welcome addition to any home keeping it comfortably warm far longer than forced air and baseboard heating systems.
How do i test my thermostats gfci.
For reference only i have 2 other floors in my house that have this same type of system.
The comfort you deserve indulge in the soothing warmth of floor heating in your bathroom kitchen or any room in the house.
The ground fault protection will guard against electrical hazards in case the electrical floor system is damaged.
Set the thermostat to heat the floor 2.
If you have a gfci breaker that could be the cause and it could also be because there is resistance between the wire and the ground.
Use a thermostat with the gfci built into it.
If the thermostat does not trip the gfci reattach the mat cable load wires to thermostat terminals 1 4 and set the.
Why wont my thermostat hold information.
When you ve installed a thermostat for a heated flooring system if you see gfi displayed on the screen that means that there may be a ground fault in the system.
There are three ways this can be done.
Nvent nuheat electric floor heating systems provide you the comfort of an energy efficient maintenance free heating alternative with no cold spots and 25 year product warranty.
Some thermostat configurations can be modified via.
Why is my thermostat stuck on the warmup.
According to the national electric code nec the electric floor warming sytem has to be gfci protected.
I found one morning 2 weeks ago that the floor was cold and saw that the gfci had tripped on my honeywell th115 af ga thermostat.
Click here to complete the thermostat backplate replacement form.
If the thermostat trips the gfci with no load attached then the thermostat s gfci will need to be replaced.
The thermostat displays the percentage of heating time required to maintain the desired.